Thermal performance characteristic value for Halfen Balcony connections HIT-HP MV, HIT-SP MV, HIT-HP ZV und HIT-SP ZV

Choose your type of wall:

 Monolithic HIT-HP MV, HIT-SP MV

Installation diagram for monolithic masonary

Thermal transmission coefficent, standard cross section

"Exterior wall": U=0,211 - 0,455 W/(m² K)
External wall (monolithic): width t=36,5 cm (λ = 0,08 - 0,18 W/(mK))

Floor construction (indoor):

  1. Cement screed 5 cm (λ=1.35 W/(mK))
  2. Footfall insulation 3 cm (λ=0.035 W/(mK))
  3. Reinforced concrete floor 18 cm (λ=2.3 W/(mK))
  4. Edge insulation strips 1 cm (λ=0.14 W/(mK)))
  5. monolithic masonry


The following calculated values are based on the datas of annex 9 according to the Buliding Authority Approval No. Z-15.7.-239 of 11th June 2013.

 Next step

 ETICS HIT-HP MV, HIT-SP MV

Installation diagram for masonary according to ETICS

Standard cross section for Thermal transmission coefficient "Exterior wall"
U=0,111 - 0,227 W/(m²K)
Thermal insulation exterior wall:
Thickness t1 = 14 - 30cm (? = 0.035W/(mK))

Exterior(Lime-sandstone):Thickness t2=24cm (? = 0.99 W/(mK))

Floor construction (interior):

  1. Cement screed 5 cm (?=1.35 W/(mK))
  2. Footfall insulation 3 cm (?=0,035 W/(mK))
  3. Reinforced concrete floor 18 cm (?=2,3 W/(mK))
  4. Edge insulation strips 1 cm (?=0,14 W/(mK)))
  5. Lime-sandstone masonry


The following calculated values are based on the datas of annex 9 according to the Buliding Authority Approval No. Z-15.7.-239 of 11th June 2013.

 Next step

 ETICS HIT-HP ZV, HIT-SP ZV

Application condition for masonry walls

Linear thermal transmittance standard „Exterior wall“ section

  • U = 0,227 W/(m² K) for insulation thickness t1 of ETICS of 14 cm
  • U = 0,149 W/(m² K) for insulation thickness t1 of ETICS of 22 cm
  • U = 0,111 W/(m² K) for insulation thickness t1 of ETICS of 30 cm
    • Insulation of Exterior wall: Thickness t1 = 14, 22 or 30 cm (λ = 0,035 W/(mK))
    • Exterior wall (Lime stone brick): Thickness t2 = 24 cm (λ = 0,99 W/(mK))
    • Floor construction (indoor):
      • 1. screed 5 cm (λ = 1,35 W/(mK))
      • 2. foot-fall insulation 3 cm (λ = 0,035 W/(mK))
      • 3. reinforced concrete slab h = 16 cm (λ = 2,3 W/(mK)) for shear bars Ø6 und Ø8 mm, reinforced concrete slab h = 18 cm (λ = 2,3 W/(mK)) for shear bars Ø10 und Ø12 mm
      • 4. edge insulation 1 cm (λ = 0,14 W/(mK))
      • 5. Lime-stone brick
      • 6. External insulation (ETICS)


The following calculated values are based on the datas of annex 9 according to the Buliding Authority Approval No. Z-15.7.-239 of 11th June 2013.